UV92 – UV Curable Masking Gel

 

 

HumiSeal® UV92 is a soft, one part, UV curable masking material. HumiSeal® UV92 applies easily because of its shearing thinning viscosity profile and is 100% cured by exposure to UV to provide a temporary barrier to prevent ingress of coatings into keep out areas. HumiSeal® UV92 has excellent solvent resistance that provides selective release from conformal coating. HumiSeal® UV92 will survive intermittent exposure to temperatures up to 150°C. HumiSeal® UV92 is REACH and RoHS compliant and available in bulk and syringes.

Properties of HumiSeal® UV92

Specific Gravity at 25°C 1.04
Viscosity Thixotropic paste
Appearance Milky white
Chemical Class Urethane acrylate
Shelf Life, DOM 12 months, stored at 18 +/-10 °C
Recommended Curing Conditions UV-LED at 365nm or 405nm “H” type microwave or arc lamp (minimum power of 200 mW/cm2)
Cleanup Solvent Isopropyl alcohol
Glass Transition Temperature (Tg) -50 °C
Hardness 40 Shore A
Elongation at Break > 200 %
Operating Temperature Range -50 to 150 °C
  • Applies easily by syringes, dispensing machines.
  • Keeps contact points and connections free of coating.
  • Will not tarnish gold, tin, copper, phosphor bronze and Sn/Pb solder.
  • Easily removed by peeling – leaves no residue to interfere with subsequent operations.

Application of HumiSeal® UV92

Apply HumiSeal® UV92 at a thickness up to 5 mm to areas on a printed circuit board where coating is not desired. Cure HumiSeal® UV92 under recommended UV exposure indicated above before applying a HumiSeal® conformal coatings. Remove HumiSeal® UV92 from the completed board by gently peeling it away from the surface of the protected area.

Availability

HumiSeal® UV92 is available in: 30CC, 55CC, 340CC, 1 liter, and 5 liter containers.

Storage

HumiSeal® UV92 should be stored between 8 °C and 28 °C in tightly closed containers away from direct sunlight and light sources.

Caution

Application of HumiSeal® UV92 should be carried out in accordance with local and National Health and Safety regulations. Use only in well-ventilated areas to avoid inhalation of vapor. Avoid contact with skin and eyes.

Consult SDS prior to use.

Get a Free Humiseal Sample