HumiSeal's thinners are specifically formulated to be used in conjunction with specific coating products. To insure that you are inquiring about the correct thinner, please view the technical datasheet for your specific coating. The appropriate thinner is identified on the datasheet, be aware that there may be two different thinners referenced on the datasheet. This difference is directly related to your specific application method. Once you have identified the correct thinner you can return to this page to obtain the technical datasheet (TDS) and material safety datasheet (MSDS) for the correct thinner.

Property503521535600604605701800801802905
Chemical Type Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary Proprietary
Average Wt.(lbs) /Gal @ 20°C 7.07 7.24 7.24 8.07 7.72 5.86 10.59 7.17 7.21 7.17 6.42
Specific Gravity 0.85 0.87 0.87 0.96 0.96 0.72 1.34 0.86 0.87 0.86 0.77
Relative Evaporating Rate (BuAc =1) 3.77 0.6 1.5 0.37 0.3 3.18 1.33 2.78 2.04 2.78 >1
Boiling Point (°F) 180 279 230 286 286 209 284 208 246 208 214
Boiling Point (°C) 80 137 110 141 141 98 140 98 119 98 101
Vapor Pressure (mmHg) 45.4 19.4 45.4 3.8 3.8 85 3.8 34 26 34 2.8
Vapor Density (Air=1) 4 3.6 4 4.6 4.6 2 4.6 4 4.2 4 4
Flash Point (°F) 30 80 40 116 53 30 71 60 60 16 22
Flash Point (°C) -1 27 4 47 12 -1 22 16 16 -9 -6
VOC(grams/liter) 843 868 868 969 959 702 127 <17 250 None 770
Shelf Life (from date of shipment) 18 months 18 months 18 months 18 months 18 months 18 months 18 months 18 months 18 months 18 months 18 months
Color clear clear clear clear clear clear clear clear clear clear clear

Key to chart

1 - Fed. Std. 141 Method 4044
2 - Fed. Std. Method 4287
3 - Volatile Organic Compounds
4 - Fed. Std. 141 Method 4061
5 - MIL-I-46058C
6 - MIL-I-46058C
7 - ASTM D1 50 65T
8 - ASTM D1 50 65T
9 - Very Easy = Can be easily removed by solvents or burn through.
    Easy = Not easily removed by solvents however can be removed by Strippers, burn through or removed mechanically.
    Moderate = Must be either mechanically removed or by using special Strippers.
    N/A = Coating not considered to be rework able.

Product Descriptions

503
Recommended for dip/brush application of all HumiSeal solvent-based conformal coatings

521
recommended for spray application of all HumiSeal solvent-based conformal coatings

535
Recommended for use with 1B51 and 2 Component conformal coating formulations

600
Recommended for spray application of all EPA grade conformal coatings

604 - Recommended for Dip/Brush application of all EPA grades

605 - Recommended for Dip/Brush application of 1B31 EPA

701
Recommended for use with LOC grade conformal coatings

800/801
Recommended for use with LSE grade conformal coatings

802
Recommended for use with UV40 and 100% solids conformal coatings.

905
Recommended for use with 1B51 NS and NSLU formulations

Disclaimer

All values contained herein are typical values. Please consult the Technical Data Sheet for the specific product to obtain complete information and detailed specification ranges and physical properties